Pengaruh Variasi Temperatur Air 7°C, 17°C, dan 27°C Pada Campuran Beton Terhadap Nilai Kuat Tekan Beton Struktural

  • Niken Indriyani Politeknik Negeri Banyuwangi
  • Mirza Ghulam Rifqi Politeknik Negeri Banyuwangi
  • M. Galuh Khomari Politeknik Negeri Banyuwangi
DOI: https://doi.org/10.52158/jaceit.v2i1.77
I will put the dimension here
Keywords: Beton, suhu air, reaksi hidrasi, slump, kuat tekan

Abstract

This study discusses the effect of water temperature variations of 7°C, 17°C, and 27°C on concrete mixes on compressive strength values ​​of structural concrete. Concrete is a material that is often used in civil engineering construction. The use of concrete in large volumes causes the heat temperature of the hydration reaction to increase. It is necessary to monitor the temperature of the water in the concrete mixture to reduce the excess heat due to the hydration reaction. Water temperature is adjusted according to the planned temperature of 7°C, 17°C, and 27°C to determine the effect on the compressive strength and workability values. Concrete compressive strength testing is carried out at 3, 7, 14, and 28 days. The number of specimens needed was 36 cylindrical samples with a diameter of 15 cm and a height of 30 cm. The results of slump testing at 7°C, 17°C, and 27°C respectively 3 cm, 5 cm and 10 cm. And for testing the compressive strength of concrete obtained data respectively 30.06 MPa, 35.31 MPa and 45.09 MPa. Increased compressive strength of concrete in each variation of 0.2%, 17.7% and 24.3%.

References

ACI 207 4R. 1998. Cooling And Insulting Systems For Mass Concrete.United America : American Concrete Institute.

Aiyub. 2010. Pengaruh Variasi Suhu Terhadap Kuat Tekan Beton. Jurnal Teknik Sipil, Vol.3-11.

Harry. 2015. Analisa Pengaruh Temperatur Air Terhadap Kuat Tekan Beton. Jurnal Teknik Sipil, 2-9.

SNI 03-1968. 1990. Metode Pengujian Analisa Saringan Agregat Halus Dan Kasar. Jakarta: Badan Standarisasi Nasional.

SNI 03-2847. 2019. Persyaratan Beton Struktural Untuk Bangunan Gedung Dan Penjelasan. Jakarta: Badan Standarisasi Nasional.

SNI 03-4142. 1996. Metode Pengujian Jumlah Bahan Dalam Agregat Yang Lolos Saringan No. 200 (0,075 mm). Jakarta: Badan Standarisasi Nasional.

SNI 03-4428. 1997. Pemeriksaan Kadar Lumpur Pasir. Jakarta: Badan Standarisasi Nasional.

SNI 15-2049. 2015. Semen Portland. Jakarta: Badan Standarisasi Nasional.

SNI 1970 . 2008. Cara Uji Berat Jenis Dan Penyerapan Air Agregat Halus. Jakarta: Badan Standarisasi Nasional.

SNI 2493 . 2011. Tata Cara Pembuatan Dan Perawatan Benda Uji Beton Di Laboratoirum. Jakarta: Badan Standarisasi Nasional.

SNI 6880. 2016. Spesifikasi Beton Struktural. Jakarta: Badan Standarisasi Nasional.

Published
2021-08-02
How to Cite
Indriyani, N., Rifqi, M. G., & Khomari, M. G. (2021). Pengaruh Variasi Temperatur Air 7°C, 17°C, dan 27°C Pada Campuran Beton Terhadap Nilai Kuat Tekan Beton Struktural. Journal of Applied Civil Engineering and Infrastructure Technology, 2(1), 12-18. https://doi.org/10.52158/jaceit.v2i1.77
Section
Articles