The Effect of Pipeline Length and Number of Fittings on Pressure Drop in a Multi-Line Gas Manifold System at PT. X Laboratory

Authors

  • Erixzen ShenaPutra Eswono Universitas Gresik
  • Lisa Puspita Ariyanto Universitas Gresik
  • Dedy Rachman Ardian Universitas Gresik

DOI:

https://doi.org/10.52158/jamere.v6i2.1648

Keywords:

Pressure Drop, Gas Manifold System, pipeline length, Fluid Mechanics, fittings

Abstract

A gas manifold system is an essential infrastructure in industrial laboratories that distributes gas from storage cylinders to multiple points of use through a piping network. System performance is strongly influenced by pipeline length and the number of fittings, both of which contribute to energy losses during fluid flow and result in pressure drop. Excessive pressure loss may reduce gas supply stability, affect laboratory equipment performance, and decrease distribution efficiency. This study aims to analyze the effects of pipeline length and the number of fittings on pressure drop in a multi-line gas manifold system at PT. X Laboratory, both partially and simultaneously, and to identify the most influential variable. This research employed a quantitative approach using an explanatory observational method. Primary data were collected through field observations and direct measurements using pressure gauges, measuring instruments, observation sheets, and technical documentation. The independent variables were pipeline length (X₁) and the number of fittings (X₂), while the dependent variable was pressure drop (Y). Data were analyzed using descriptive statistics, classical assumption tests, multiple linear regression, t-tests, F-tests, and the coefficient of determination with the assistance of SPSS Statistics software. The theoretical framework was based on fluid mechanics principles, including the continuity equation, Bernoulli equation, Darcy–Weisbach equation, and the concepts of major and minor losses. The findings are expected to provide a scientific basis for evaluating piping network configurations, optimizing gas distribution systems, minimizing pressure losses, and improving the reliability and operational efficiency of multi-line gas manifold systems.

References

[1] Compressed Gas Association. (2020). Handbook of Compressed Gases (5th ed.).

[2] ASTM International. (2021). ASTM MNL 35: Manual for the safe use of compressed gases in laboratory environments.; Compressed Gas Association (CGA). (2020). Handbook of Compressed Gases (5th ed.).

[3] Çengel, Y. A., & Cimbala, J. M. (2018). Fluid Mechanics: Fundamentals and Applications (4th ed.). McGraw-Hill.

[4] Fox, R. W., McDonald, A. T., Pritchard, P. J., & Leylegian, J. C. (2020). Fox and McDonald's Introduction to Fluid Mechanics (9th ed.). John Wiley & Sons.

[5] White, F. M. (2021). Fluid Mechanics (9th ed.). McGraw-Hill Education.

[6] Munson, B. R., Young, D. F., Okiishi, T. H., & Huebsch, W. W. (2021). Fundamentals of Fluid Mechanics (9th ed.). John Wiley & Sons.

[7] Crane Co. (2018). Flow of Fluids Through Valves, Fittings, and Pipe (Technical Paper No. 410). Crane Co.

[8] Bai, Q., & Bai, Y. (2014). Subsea pipeline design, analysis, and installation. Elsevier.

[9] Bambore, A., Hendrick, P., & Ponthot, J.-P. (2026). Study, modelling and computing of pressure losses in GH2 pipelines. Energies, 19(4), 885. https://doi.org/10.3390/en19040885.

[10] Sherza, J. S. (2024). Theoretical investigation of the major and minor losses in pipes and fittings. Journal of Engineering and Sustainable Development.

[11] Kogut, K., Kapusta, K., & Stańczyk, K. (2025). Changes in the operating conditions of distribution gas networks as a function of altitude conditions and the proportion of hydrogen in transported natural gas. Hydrogen, 6(4), 82.

Published

2026-08-01

Issue

Section

Articles

How to Cite

The Effect of Pipeline Length and Number of Fittings on Pressure Drop in a Multi-Line Gas Manifold System at PT. X Laboratory. (2026). Journal of Applied Mechanical Engineering and Renewable Energy, 6(2), 85-93. https://doi.org/10.52158/jamere.v6i2.1648