Evaluasi dan Re-Mapping APAR di Lingkungan Gedung Perkantoran PLN UID Jawa Timur

  • Deny Nurcahyo Hari Prastya Universitas Airlangga
  • Tri Martiana Universitas Airlangga
  • Parlan PT. PLN (Persero) Unit Induk Distribusi Jawa Timur
DOI: https://doi.org/10.52158/jaceit.v6i2.976
I will put the dimension here
Keywords: PFE, Portable, Fire, Extinguisher, Mapping

Abstract

This research aims to evaluate and re-map the Portable Fire Extinguishers (PFE) in the office buildings of PLN UID East Java. The method employed is a descriptive observational approach, gathering primary data through direct observation and structured interviews, supplemented by secondary data from document reviews. The findings reveal a gap between fire safety standards and actual conditions, such as improper PFE placement, unclear expiration dates, and an uneven distribution of PFE across buildings. Risk analysis identifies hazards from these issues, including delayed fire response and potential failure of PFE during emergencies. Calculating PFE needs based on Permenakertrans Regulation No. 04/MEN/1980 and NFPA-10 edition 2022 generates recommendations for redistributing PFE. Based on these calculations, three buildings (C, F, I) are found to have an excess of 13 PFE, while four buildings (A, B, D, E) are short by 9 PFE. The recommendation suggests transferring 11 PFE from Building F: 4 PFE to Building A, 3 PFE to Building B, and 2 PFE each to Buildings D and E. This redistribution ensures the correct number of PFE in each building, enhancing fire safety management in PLN UID Jawa Timur office buildings. This action aims to align the PFE distribution with safety requirements.

References

L. Kuncoro, V. Rivai Zainal, and A. Hakim, “Fire Emergency Action Plan In The Indonesia Stock Exchange Building,” Int. J. Adv. Multidiscip., vol. 1, no. 4, pp. 376–387, 2023, doi: 10.38035/ijam.v1i4.150.

J. Kim et al., “An experimental study on the performance of fire extinguishing system according to the agent charging condition and nozzle type.,” Heliyon, vol. 9, no. 9, p. e19473, Sep. 2023, doi: 10.1016/j.heliyon.2023.e19473.

M. L. Ashari, S. N. Ulfah, and S. P. Agustin, “Analisis Kesesuaian Alat Pemadam Api Ringan Berdasarkan Permenakertrans No. 4 Tahun 1980 di Area Workshop Mekanik Perusahaan Galangan Kapal,” IJESPG (International J. Eng. Econ. Soc. Polit. Gov., vol. 1, no. 3 SE-Articles, pp. 13–20, Jul. 2023, doi: 10.26638/ijespg.v1i3.28.

T. Bagheri, S. F. Forghani, S. Hoveidamanesh, M. Asgari, O. Mahboubi, and M. Momeni, “An Assessment of the Fire Safety Standards in Iranian Homes and Equipment As They Relate to Fire Accidents.,” Ann. Burns Fire Disasters, vol. 37, no. 1, pp. 10–16, Mar. 2024.

A. P. Pramayu, H. N. Rahmawati, A. A. Tantia, A. P. Putra, and R. N. Fauzia, “Tinjauan Persepsi Penghuni Gedung Terhadap Sistem Proteksi Kebakaran di Gedung Y Tahun 2022 sebagai Bagian dari Budaya K3,” Malahayati Nurs. J., vol. 5, no. 3, pp. 670–684, Mar. 2023, doi: 10.33024/mnj.v5i3.8059.

A. Purwanto, “Training dan Simulasi Penggunaan Alat Pemadam Api Ringan (APAR) dan Hydrant di Industri,” J. Community Serv. Engagem., vol. 4, no. 1 SE-Articles, pp. 11–15, Apr. 2024, doi: 10.9999/jocosae.v4i1.198.

F. Nasution, A. Syahfira, S. Kholijah, and A. S. Pulungan, “Evaluasi Standar Peletakan Alat Pemadam Api Ringan (APAR) di Kantor BPBD Provinsi Sumatera Utara,” Shihatuna J. Pengabdi. Kesehat. Masy., vol. 1, no. 2, p. 53, 2021, doi: 10.30829/shihatuna.v0i0.9283.

R. Kurniawan, A. Asril, and E. P. Rahayu, “Evaluasi Sistem Tanggap Darurat Kebakaran Dan Preparedness (Kesiapan) Sebagai Langkah Penanggulangan Kondisi Darurat Kebakaran Di Rumah Sakit 3m Plus Tembilahan,” Media Kesmas (Public Heal. Media), vol. 1, no. 2, pp. 225–240, 2021, doi: 10.25311/kesmas.vol1.iss2.53.

S. B. A. F. Kuswandi, F. Ayu, R. A. Ratriwardhani, and E. H. Pratiwi, “Evaluasi Pemeriksaan APAR Di PT Lintech Duta Pratama,” Community Dev. J. J. Pengabdi. Masy., vol. 5, no. 4 SE-Articles, pp. 7714–7718, Aug. 2024, doi: 10.31004/cdj.v5i4.31157.

Kementerian Ketenagakerjaan Republik Indonesia, “Permennakertrans No : 04/MEN/1980 tentang Syarat-Syarat Pemasangan dan Pemeliharaan Alat Pemadam Api Ringan,” Republik Indonesia. 1980.

Kepmenakertrans, “Keputusan Menteri Tenaga Kerja RI No. KEP.186/MEN/1999 tentang Unit Penanggulangan Kebakaran di Tempat Kerja.” 1999.

Kementrian Pekerjaan Umum, “Permen PU No. 26/PRT/M/2008 Tentang Persyaratan Teknis Sistem Proteksi Kebakaran pada Bangunan Gedung dan Lingkungan.,” Republik Indonesia. 2008.

National Fire Protection Association, “NFPA-10: Standard for Portable Fire Extinguisher,” NFPA. 2022. [Online]. Available: www.nfpa.org.

Published
2025-08-04
How to Cite
Prastya, D. N. H., Martiana, T., & Parlan. (2025). Evaluasi dan Re-Mapping APAR di Lingkungan Gedung Perkantoran PLN UID Jawa Timur. Journal of Applied Civil Engineering and Infrastructure Technology, 6(2), 99 - 105. https://doi.org/10.52158/jaceit.v6i2.976
Section
Articles